Wednesday, November 30, 2011

Carrier Bryant HC30GB232 Furnace Inducer Blower Motor

!±8± Carrier Bryant HC30GB232 Furnace Inducer Blower Motor

Brand : Carrier | Rate : | Price :
Post Date : Nov 30, 2011 09:15:10 | Usually ships in 1-2 business days

Carrier Bryant HC30GB232 Inducer Blower Motor Used In: 48GJD006   500   48GJD008   500   48GJD012   500   48GJE006   500   48GJE008   500   48GJE012   500   48GJF006   500   48GJF008   500   48GJF012   500   48HED005   300   48HED005   500   48HED006   300   48HED006   500   48HEE003   300   48HEE004   300   48HEE004   500   48HEE005   300   48HEE005   500   48HEE006   300   48HEE006   500   48HEF004   300   48HEF004   500   48HEF005   300   48HEF005   500   48HEF006   300   48HEF006   500   48HEG005   500   48HEG006   500   48HEH004   500   48HEH005   500   48HEH006   500   48HEK004   500   48HEK005   500   48HEK006   500   48HEL005   300   48HEL005   500   48HEL006   300   48HEL006   500   48HEM003   300   48HEM004   300   48HEM004   500   48HEM005   300   48HEM005   500   48HEM006   300   48HEM006   500   48HEN004   300   48HEN004   500   48HEN005   300   48HEN005   500   48HEN006   300   48HEN006   500   48HER003   300   48HER004   300   48HER004   500   48HER005   300   48HER005   500   48HER006   300   48HER006   500   48HES005   300   48HES005   500   48HES006   300   48HES006   500   48HET004   300   48HET004   500   48HET005   300   48HET005   500   48HET006   300   48HET006   500   48HJD00511 650   48HJD005W  55    48HJD005   330   48HJD005   340   48HJD005   350   48HJD005   360   48HJD005   530   48HJD005   540   48HJD005   550   48HJD006W  54    48HJD006X  54    48HJD006   330   48HJD006   340   48HJD006   350   48HJD006   530   48HJD006   540   48HJD007W  55    48HJD007X  55    48HJD007   530   48HJD007   540   48HJD007   550   48HJD008U

Welch Allyn Otoscope Set Buy Purchasing Cheap Corner Curio Cabinets Led Step Lighting Save

Sunday, November 20, 2011

Carrier, Bryant, Payne Furnace Inducer Blower Motor Assembly

!±8± Carrier, Bryant, Payne Furnace Inducer Blower Motor Assembly

Brand : | Rate : | Price :
Post Date : Nov 21, 2011 01:11:14 | Usually ships in 1-2 business days

Carrier, Bryant, Payne Furnace Inducer Blower Motor Assembly

Wholesale Bulova Accutron Hoover Shampooers Discounted

Friday, November 4, 2011

Low Air Flow From A Furnace

!±8± Low Air Flow From A Furnace

Low air flow to certain rooms or areas of a building is one of the complaints we hear all the time. Buildings with several levels and only one central furnace and air conditioner usually have trouble getting each floor the same temperature for several reasons.

The thermostat is usually on the middle floor. Once the middle floor temperature has reached the set point of the thermostat, the furnace or air conditioning system will shut off whether or not the other floors are at that temperature or not. If the building was built using a system for each floor the problem would not exist because each floor would have it's own thermostat. It is often possible to install a second system in a home or building. Doing this, would involve adding a second furnace or air handler, another air conditioner, running new refrigerant lines, a thermostat and all related secondary and primary 120 volt and 230 volt wiring. Often times, however this is not feasible for many reasons.

Another choice might be to install zoning to the existing furnace if it is possible to somehow separate the ductwork in a manner that will allow the zoning to work correctly. Zoning works by having electronic dampers installed in the ductwork, adding a zoning panel and various thermostats. The only time these dampers open and let heated or cooled air into a room is if there is a signal from the zones thermostat. The cost on most zoning jobs runs about ,500.00 to ,000.00 depending on the complexity of the job.

A higher 1,625 R.P.M direct drive blower motor can usually be installed which will move more air to all registers. Once this has been done you can damper down on smaller room registers like bathrooms really boost the air where it is needed.

Still another way to help even out a building temperature is to balance the system. Balancing is done by measuring the amount of air flow coming out of the registers, determining with a heating and cooling load survey what the actual requirement are for the rooms and then adjusting the registers to get the required air flow from each register. Balancing will never replace separate systems or zoning but it will make the building much more even and won't cost an arm and a leg to get done. Most quality Heating and Air Conditioning companies can do a balancing job at a reasonable cost.


Low Air Flow From A Furnace